Adjust ball amounts on a ball dispenser with BA16 circuit board
The menu system is operated using the Rotary Dial. To display the menu, turn the Dial clockwise.
Navigate the menu by turning the Dial clockwise or anti-clockwise.
To edit a menu item ‘click’ the dial by pressing it inwards towards the circuit board until it clicks.
Adjustments to the value is made by turning the Dial clockwise (increase) or anti-clockwise
(decrease). Once desired value is achieved click the dial again to save the new value.
The display will go back into standby after some time of inactivity.
Menu Items
Speed Lo
This value adjusts the speed of the motor when there are five balls or less left to dispense.
This is to make sure the motor has time to stop once correct ball amount is achieved.
Default value: 25
Speed Hi
This value adjusts the speed of the motor when running at full speed.
Default value: 100
Pay 1
Sets the amount of balls to dispense when a pulse is given on Pay Channel 1
Pay 2
Sets the amount of balls to dispense when a pulse is given on Pay Channel 2
Pay 3
Sets the amount of balls to dispense when a pulse is given on Pay Channel 3
Pay 4
Sets the amount of balls to dispense when a pulse is given on Pay Channel 4
Pay 5
Sets the amount of balls to dispense when a pulse is given on Pay Channel 5
Pay 6
Sets the amount of balls to dispense when a pulse is given on Pay Channel 6